Maintenance of the Bitron 25 : UV and quartz lamp
DIY DIY · A report by Jean-Michel
This report shows the replacement of a Bitron 25 UV lamp and the cleaning of its quartz tube.
The average lifetime of a UV lamp is approximately 9,000 hours continuously.
It should be noted that this lifetime will vary depending on its use which will not be constant.
It is usually stopped during the winter period but also during the season for introduction of bacteria (minimum 48 h) or if circumstances make its use unnecessary.
This means that it can reasonably be said that the lamp's lifetime will be optimal over 2 seasons. Then the efficiency decreases which makes an unnecessary consumption of electricity for a lamp that only gives sometimes lower efficiency.
40 to 50% of the original
I suggest you see below.
how to change the UV lamp of a BITRON 25 by taking advantage of the annual quartz cleaning at the end of the season
Change of the BITRON UV lamp
To start you need a cruciform screwdriver, vaseline (or paraffin oil) and a dry cloth.

First, remove the 4 screws on the side of the BITRON to remove the protective hood.

By removing the hood, the electrical connection to which the UV lamp is connected is seen in white.
The gasket is also removed from the hood.


The next step is to remove the 4 screws from the cover allowing access to the quartz in which the UV lamp is located.

The white electrical connection can be removed by shooting at it (2 bits allow to grab it to pull it.

We renew all these operations on the other side and remove the UV lamp


If cleaning of your quartz is necessary (this is the case at least once a year) you must push it inwards which will allow you to remove it from the other side.
Pick up the seal around the quartz and put it aside.


Remove the quartz and clean it.
If it turns out that quartz is covered with a limestone layer that you only
can remove, just let it soak one night in vinegar.
He'll be like new again!

That's it!The cleaning is over!...
For the non-handicrafters who always have at the end an extra room I advise you to drop them off.
parts in the order of disassembly on the side

Think about putting vaseline or paraffin oil on your joints before repositioning them
Put the seal back on the quartz and put it back in place


Put the new lamp back in place and slide it. Put the 4 screws back on and put the white electrical connection back in place


Replace the bonnet joint after coating it with vaseline (or paraffin oil) and reposition the bonnet.
Practice the same way for the other side

Stay
to verify the operation of the UV lamp by the pane provided for this purpose
and keep it dry while waiting for the good days!


Jean-Michel
Jean-Michel for Aquatechnobel.
Back to the various filters