AQUATECHNOBEL · Technical encyclopedia of airlift
← Technical guide contents

4. Comparison with an electric water pump

Calculation for an electric water pump of 10,000 L/h

The consumption varies according to the models and their setting. The data provided mention the announced power levels from 63 to 85 W for some economical models:

Other examples provided are 155 W or 250 W. Higher power alone does not allow a pump to be classified as less efficient: it may correspond to a different discharge height. Commercial references and their characteristics remain to be verified on the specifications of the exact models.

Example at 80 W

For a power of 63 W and a flow rate actually delivered of 10 m³/h, the ratio is 6.3 W/(m³/h).

ScenarioFlow usedPowerRatio W/(m³/h)
Water pump10 m³/h63 W6,3
Water pump10 m³/h80 W8
Water pump10 m³/h85 W8,5
Water pump10 m³/h155 W15,5
Water pump10 m³/h250 W25

Conclusion of the comparison

SystemFlow rate (m³/h)Estimated powerRatio W/(m³/h)
Airlift (data attributed to Marcje, 20 L)17About 20 WAbout 1.2
Airlift (data attributed to Marcje, 40 L)23About 40 WAbout 1.7
Electric water pump — cost-effective scenario1063 to 85 W6.3 to 8.5
Electric water pump — 155 W scenario10155 W15,5

Taking as a reference a water pump delivering 10 m³/h for 80 W, the two d-airlift scenarios correspond to about 4.6 to 6.8 times less energy per cubic metre moved, about 4 to 7 times. This is a conditional comparison based on the values provided, not a guaranteed advantage over any installation.

In this reduction scenario, a flow rate of 8.5 m³/h for 20 W gives 20 ÷ 8.5 的 2.35 W/(m³/h). This ratio remains lower than the water pump scenarios presented, subject to comparison of operating heights and equivalent measurements.

← Back to contents