5. Comparison of air pumps

The ratio is calculated by dividing the watts by the m³/h, expressed in W/(m³/h), equivalent to Wh/m³.

Comparison with Marcje's airlift measurements

The figures provided for this file describe ideal conditions. The detailed sources and conditions of the tests are still to be found.

Designated air pumpAnnounced water flowApproximate power providedCalculated ratio
20 L17 m³/h20 W20 - 17 - 1.18 W/(m³/h)
40 L23 m³/h40 W40 23 1.74 W/(m³/h)

On these values, the "40 L" configuration moves more water, but consumes more energy per cubic metre displaced. The 20 L and 40 L designations do not demonstrate the power absorbed or the air flow at the operating depth.

📈 Table of measures of a "German neighbour" (Thomas pumps)

One member shared the measurements of a German user, fan of airlift and Thomas pumps. These data compare two models of pumps at different pressures.

PumpPressureConsumptionAirflowPerformance (L/min/W)
Thomas AP60N100 mbar38 W80 L/min2,11
Thomas AP60N200 mbar30 W44 L/min1,47
Thomas AP 60/80100 mbar50 W96 L/min1,92
Thomas AP 60/80200 mbar40 W63 L/min1,58

This member also notes a discrepancy between these measurements and the specifications of the manufacturer Thomas.