Understanding airlift
Make water circulate with air
An airlift allows water to be moved by means of an air pump. In the pond, no propeller directly pushes the water: air is injected into the lower part of a vertical tube, called a lift tube.
The bubbles go up into the tube and bring water with them. The mixture of water and air is less dense than the water that surrounds the tube. This difference allows the water to enter from the bottom and go up to the outlet.
At the outlet, the air is evacuated and the water continues to the pond or to another tank. The shape of the outlet and the separation of the air are therefore part of the assembly.
The airlift consumes electricity via its air pump. Its interest is judged on the water flow actually obtained for the measured electrical power.
Why Immersion is Important
In order to operate, the lift tube must be sufficiently immersed. The depth of injection is measured between the water surface and the point where the air enters the tube.
A deeper injection gives bubbles a longer journey, but also imposes more pressure on the air pump. At this higher pressure, the same pump usually provides less air. Increasing depth does not guarantee a better result alone.
As a physical marker, one metre of water represents about 0.1 bar of hydrostatic pressure, including losses in air pipes, fittings and injection devices.
Injection depth and lift height: two different measurements
| Measure | What it represents |
|---|---|
| Injection depth | Vertical distance between the water surface on the supply side and the point of air injection. |
| Lift height | Elevation that the installation must take through water, e.g. to an outlet above the power supply level. |
| Difference in level in operation | Disparity between water surfaces in the pond and the different tanks when the water flows. |
A tube can be deeply immersed while discarding water near the surface level. This is the situation, with a low height to pass, which is particularly suitable for airlift pond facilities.
Airlifts in gravity-fed filtration
In a gravity-fed circuit, the pond and the connecting vats return to the same water level at the stop, if nothing isolates them. In operation, the resistances of the pipes and filters create level deviations.
An airlift placed at the end of filtration can return the water to the pond. By removing water from the last tank, it maintains circulation from the pond through the filtration stages.
It is necessary to provide for sufficiently wide water passages and to limit bottlenecks. A cracked grid, too narrow pipes or many elbows can greatly reduce the flow.
What affects the flow rate
- Air available at the actual pressure: The zero-pressure flow rate on an air pump is not sufficient to select the equipment.
- Injection depth: it affects the pressure required and the behaviour of the mixture in the tube.
- Tube diameter: It must be consistent with the amount of air injected and the water flow sought.
- Injection: the diffuser or pressure chamber shall distribute the air in a manner suitable for assembly.
- The exit: Its height, elbows and air evacuation influence the operation.
- The complete circuit: entrances, pipelines, filters and their soiling determine the resistance to defeat.
There is no universal ratio to deduce a water flow from the air flow alone. A measurement obtained on one installation does not automatically transpose to another.
What are the benefits for the pond?
In a circuit designed for low lift height, the airlift can move an interesting water flow with limited electricity consumption. It also provides an exchange between air and water, and the lift tube does not have any mechanical parts in rotation.
However, the effect on oxygen depends on the conditions: temperature, oxygen already present, air flow rate and quality of exchange. The airlift alone does not guarantee sufficient oxygenation for all fish and all filtration.
The energy gain shall be checked at water flow rates and comparable operating conditions, including all the power of the air pumps required for installation.
The limits to be known
A high cascade, a pressure filter or a very resistant network can make another solution more suitable.
The assembly also requires depth, access for maintenance and proper venting of air. An increase in injected air does not improve the flow indefinitely: beyond a certain point, it can especially increase turbulence and consumption.
Finally, the scum is not automatic. To collect the scum, it is necessary to have an exit and a separation device provided for this use. This point will be covered by a separate chapter.
How do I check that a montage works well?
To compare two airlifts, the water flow rate, the actual electrical power, water levels, the depth of the injection and the circuit characteristics must be increased. The air flow at the working pressure complements these measurements usefully.
The measurement must be done with the filtration in normal operation. A free-out test gives an indication, but does not necessarily describe what will happen once the installation is connected to the pelvis.