7. Diameters and head loss

📊 Table of measures by Zenkoi (actual conditions)

This table is particularly interesting because it presents measurements made in a real installation, with pressure losses related to piping, and not under ideal laboratory conditions.

PumpColumn diameterColumn lengthFlowConsumptionReported ratio W/(m³/h)
SLL40125 mm205 cm24 000 L/h28 W1,16
SL50125 mm205 cm27,000 L/h35 W1,29
ELS120125 mm205 cm42 000 L/h107 W2,54

Important context: These measurements were carried out with a long return pipe of 14 meters in diameter 125, with 6 elbows at 45°, and a filter (drum) upstream. Zenkoi specifies that under these conditions the flow rate is approximately two times lower what Marcje had measured in ideal conditions (e.g. 11 m³/h instead of 22.5 m³/h with the same SLL-40 pump).