7. Diameters and head loss
📊 Table of measures by Zenkoi (actual conditions)
This table is particularly interesting because it presents measurements made in a real installation, with pressure losses related to piping, and not under ideal laboratory conditions.
| Pump | Column diameter | Column length | Flow | Consumption | Reported ratio W/(m³/h) |
|---|---|---|---|---|---|
| SLL40 | 125 mm | 205 cm | 24 000 L/h | 28 W | 1,16 |
| SL50 | 125 mm | 205 cm | 27,000 L/h | 35 W | 1,29 |
| ELS120 | 125 mm | 205 cm | 42 000 L/h | 107 W | 2,54 |
Important context: These measurements were carried out with a long return pipe of 14 meters in diameter 125, with 6 elbows at 45°, and a filter (drum) upstream. Zenkoi specifies that under these conditions the flow rate is approximately two times lower what Marcje had measured in ideal conditions (e.g. 11 m³/h instead of 22.5 m³/h with the same SLL-40 pump).