AQUATECHNOBEL · Technical encyclopedia of airlift
← Contents

2. ATB Airlift Generations

Classic Airlift

The classic airlift is the first version of the airlift that has been very successful. As you can see on the diagram, it consists of a main tube of 110 mm diameter.

This version is largely enough for most ponds, and nothing prevents the airlifts from multiplying. That's what I did on my personal pool, where six airlifts are in service.

Classic airlift principle diagram without vats: 110 mm lift tube, compression chamber, 20 mm air supply and two 110 mm tee vents.
Classic airlift scheme. Click on the image to enlarge it.

Membrane airlift

Diagram 2D of an airlift with membrane: rising column, exit with 90 degree elbow, inclined vent, side air duct and suction openings.
Click on the image to enlarge.

Presentation and testing of membrane airlift

The video presents membrane airlift developed by Vincent, compared to a classic airlift of 110 mm. The objective is to increase the water flow without increasing the consumption of the air pump.

The difference in construction is located mainly in the lower part :

  • An upward column of 160 mm.
  • An enlarged base of 350 mm, made of stainless steel 316 of 2 mm thick.
  • A membrane diffuser 250 mm, centered in the base.
  • The water enters through the openings of the foot, passes around the diffuser and then rises with the bubbles.
  • At the top, a 90° elbow and a tea allow water to return and degassing.

The assembly is fast once the base has been manufactured: fixing the diffuser, connecting the air, and then mounting the tube and outlet.

The trials are promising. The assembly is tested in an inner pond, with about 1.10 to 1.20 m depth and a Hiblow air pump named "80 L". Vincent announces about 25 m³/h in a previous 110 mm test, compared to about 50 m³/h with the 160 mm membrane model, for the same pump.

Two details are important to present these results correctly:

  • The announced measure of 80 liters in 5 seconds corresponds mathematically to 57.6 m³/h. The figure of 50 m³/h therefore remains an order of magnitude resulting from a bag measurement, recognized as approximate in the video.
  • Consumption 60 W is estimated, not measured by the wattmeter. The diameter and the injection device change simultaneously: the gain cannot be attributed only to the membrane.

The essential point is the dimensioning of the circuit. Vincent plans to enlarge the water passages and deepen the collector chamber to limit the head loss. The additional gain mentioned at 2 m depth remains a hypothesis to be tested.

This version illustrates a trend towards larger flows, with a simplified construction around a membrane diffuser. The video provides an encouraging test, to distinguish from a performance table validated by precise measurements.

Video associated with the schema

Watch the video on YouTube.

← Back to contents