6. Injection depth and immersion
🔬 Previous MC measurements (2008, 50 mm column)
These are older measurements, carried out with a rising column of only 50 mm diameter and an air pump of 40 litres. They show the impact of the depth of the air injection and the discharge height on the flow.
| Discharge head | Injection depth | Flow |
|---|---|---|
| 20 cm | 160 cm | 4,300 L/h |
| 20 cm | 120 cm | 3,250 L/h |
| 20 cm | 80 cm | 2 400 L/h |
| 40 cm | 160 cm | 3 000 L/h |
| 40 cm | 120 cm | 2 000 L/h |
| 60 cm | 170 cm | 1 800 L/h |
| 60 cm | 120 cm | 1,200 L/h |
These data illustrate that the deeper the air is injected and the lower the discharge height, the greater the flow.