🔬 Previous MC measurements (2008, 50 mm column)

These are older measurements, carried out with a rising column of only 50 mm diameter and an air pump of 40 litres. They show the impact of the depth of the air injection and the discharge height on the flow.

Discharge headInjection depthFlow
20 cm160 cm4,300 L/h
20 cm120 cm3,250 L/h
20 cm80 cm2 400 L/h
40 cm160 cm3 000 L/h
40 cm120 cm2 000 L/h
60 cm170 cm1 800 L/h
60 cm120 cm1,200 L/h

These data illustrate that the deeper the air is injected and the lower the discharge height, the greater the flow.