AQUATECHNOBEL · Technical encyclopedia of airlift
← Technical guide contents

Airlift: how it works, how to build it and how it performs

The advantages of airlift

With the increase in the price of energy, airlift is an interesting solution to reduce the cost of operating the pond. Based on my experience, a classic airlift can move about 10 m³ water per hour for electricity consumption from 9 to 12 W, in a suitable mounting and with a very low lift height.

This flow represents a passage of the volume of a pond of 20 m³ in two hours. It may be suitable for installation of this volume if the fish population, feed and filtration are suitable. Nothing prevents the increase of airlifts for a larger pool, provided that an airlift air pump is used.

These performances describe a return to experience. They are not guaranteed for all mountings: the depth of the injection, the air pump and the head loss directly influence the result.

An installation designed for the gravitary

In this application, the airlift is intended for gravity ponds. It works especially when the water flows between nearby levels. It can pass a small difference in level, but its flow decreases with the height to be raised: it is therefore not chosen to power a high cascade or a pressure circuit.

On this installation, it is not possible to adjust the flow rate as with a water pump equipped with a dimmer.

Particular attention should be paid to the return to the pond. Traffic should be distributed to avoid dead areas where waste is likely to accumulate.

A role in gas exchange

Depending on my experience of use, airlift maintains an open area during the cold weather and contributes to oxygenation of the pond in warm weather. In my installation, it allows to do without an extra bubbler in the pond.

However, this result depends on the assembly and needs of the fish. Check dissolved oxygen; see: Learn more about the oxygen needs of the pond.

To circulate the water in the pond with air: this is the principle of airlift. This page brings together the explanations, the documented assembly and the tests filmed by Aquatechnobel.

The test values are results announced in the videos, with their limits; they do not constitute a flow guarantee for another installation.

Compare the consumption of an airlift and an electric water pump

To compare the installations, the electrical power consumed by the water flow can be divided: power (W) ÷ flow rate (m³/h). The result is expressed in W/(m³/h), which is equivalent to Wh/m³, i.e. the energy required to move a cubic metre. The smaller the value, the less the installation consumes per volume displaced.

Example of a 10 000 L/h pump

10,000 L/h corresponds to 10 m³/h. For a pump that consumes 80 W and does deliver this flow, the calculation gives: 80 10 = 8 W/(m³/h).

The data provided for this comparison mention the announced power levels of 63 to 85 W for some economical models: KOBRE®TEC Eco Premium 10000 to 63 W, AquaForte Vario 10000 S WiFi at 85 W and SunSun NEO-10000 around 80 W. They also evoke models of 155 W or even 250 W. These references and their data sheets remain to be checked before making a product comparison.

A commercial maximum flow rate of 10 000 L/h is not necessarily the flow rate obtained in a pond. The pump curve should be consulted and ideally the flow rate and power in operation should be measured.

Airlift data allocated to Marcje

The numbers transmitted for this file are 17 m³/h for about 20 W with an air pump designated "20 L", and 23 m³/h for about 40 W with a "40 L". The names of the pumps do not prove their actual electrical power or air flow at the working pressure. The sources and test conditions of these values remain to be attached.

System / scenario providedWater flowPower used for calculationRatio W/(m³/h)
Airlift, data attributed to Marcje, pump "20 L"17 m³/hAbout 20 W1,18
Airlift, data attributed to Marcje, pump "40 L"23 m³/hAbout 40 W1,74
Water pump, cost-efficient scenario10 m³/h63 to 85 W6.3 to 8.5
Water pump, 155 W scenario10 m³/h155 W15,5
Water pump, 250 W scenario10 m³/h250 W25

With the 80 W reference for 10 m³/h, the calculated ratios are approximately 6.8 times and 4.6 times higher than those of the two airlift scenarios. This illustrates the possible energy interest of the airlift at low rise height; this does not show a universal gain of 4-7 times for all ponds.

Taking into account the real circuit

Head loss can significantly reduce the airlift flow rate. The text transmitted cites a half-fold decrease attributed to Zenkoi; its source and measurement conditions remain to be found. This factor should not be applied automatically to all mountings.

As a simple scenario, if the flow rate increases from 17 to 8.5 m³/h for an unchanged power of 20 W, the ratio becomes 20 ÷ 8.5 的 2.35 W/(m³/h).

To conclude on the real economy: compare the actually delivered flow rates, the measured power levels and the level differences in comparable circuits. Distinguish test results, commercial data and calculation assumptions.

Understanding airlift

An air pump injects air into a compression chamber located in the lower part of the vertical tube. The water-to-air mixture is less dense than the surrounding water; the bubbles rise and cause the water to exit. The air is then evacuated through the vents.

The airlift is particularly suitable for traffic with a low lift height. The head loss of pipes and filters remains decisive even in a gravity-fed circuit.

Read the detailed explanations.

Cut of an airlift with 110 mm tube, 20 mm rigid air duct and two air vents
Height specified by Patrick Vandael: 1.70 m from the base to above the elbow, without vents. Click to enlarge.

Height and installation in the tank

That said, based on my experience with this montage, the most profitable height is 1,50 m. This is dependent on the air pump and operating conditions.

We have to leave it. 10 cm clearance under the airlift At the stop, the airlift is immersed: only the vents exceed water. At the start, the level of the tank containing the airlift decreases, while the circulation settles.

For this installation, plan a tank of 1.90 m height for an airlift of 1.70 m, or a tank of 1.70 m for an airlift of 1.50 m. The clearance under the tube, the level of operating water and the margin above the water shall be checked together.

The tank must be supplied with sufficient power: the free passage section of water must be greater than that of the airlift tube. However, this section is not enough to guarantee the flow: the length of the pipes, the connections and the head loss of the filtration are also involved.

Manufacturing

The assembly shown includes a 110 mm lift tube, a compression chamber made with a 125 mm sleeve and rings from a 125/110 reduction. A 20 mm rigid tube feeds the chamber mid-height through a 90° elbow. It goes up to the top of the airlift, then a hose connects it to the air pump. Two 110 mm tees form the vents at the outlet.

The injection holes are drilled into the 1 mm drill using a gauge. The number of rows and holes must be attached to the version of the mounting: the two demonstrations do not give the same indications.

Setting of the gridded template around the tube.
Setting of the gridded template around the tube.
Displaced layout of the drills on the template.
Displaced layout of the drills on the template.
Drilling through the template.
Drilling through the template.

See the manufacturing file and video markers.

Aquatechnobel tests

Comparison of 110 mm and 160 mm

The report “Essais airlift avec 20 100 et bien plus” The classic 110 mm model is confronted with a 160 mm mounting with a 350 mm stainless steel inlet and a 250 mm membrane diffuser.

The explanations place the test facility around 1.10 to 1.20 m depth. This indication is not an accurate measure of the depth of injection. The rise height and the flow of air actually injected are not sufficiently documented to establish a dimensioning curve.

MountingAir pump announcedReported resultLimits
110 mm airliftSame announced Hiblow pump of 80 L/min.Approximately 25 m³/h, a reminder of an earlier test to 10:47.Result quoted orally; detailed protocol not provided in this extract.
160 mm airlift with 250 mm diffuserAnnounced Hiblow 80 L/min; actual flow rate at service pressure not measured in explanations.Approximately 80 litres collected in 5 seconds; reported flow rate of about 50 m³/h to 8:01.Approximate volume and duration; uncertainty of unquantified measurement.

Verification of calculation: 80 Φ 5 × 3.6 = 57.6 m³/h. The video announces about 50 m³/h. The collection values are approximate, so the two indications are kept with this explained difference, without assigning any additional precision to the test.

Consumption and efficiency

A consumption of the order of 60 W is mentioned as an estimate, with a reference to another pump. It must not be presented as an electric power measured on the Hiblow used. Therefore, a reliable measured efficiency in m³/h per watt cannot be calculated from this extract.

The gains envisaged at a depth of 2 m are assumptions made during the report, not test results at this depth.

What this comparison shows

In the context presented, stakeholders report more flow with the 160 mm mounting. However, the diameter, inlet and injection device change together: this test does not allow the gain to be attributed to the diameter alone or to guarantee a doubling of the flow over another pond.

How to document future trials

This information will enable comparable tables to be constructed and then a calculator based on documented measurements.

← Back to contents