The world of koi and garden ponds

Cross-country bottom drains

What flow rate can pass through a 110 mm bottom drain in gravity?

Count about 10 m³/h per bottom drain for a first estimate. The actual flow depends on the pipe and the difference in level available between the pond and the filter inlet.

The orders of magnitude to be retained

  • About 10 m³/h per barrel. It is a starting point for a 110 mm gravitational line. A long pipe, elbows or a partially closed valve reduce the flow rate for the same level deviation. Field reference
  • 8 to 10 m³/h to limit deposits. This range is a practical benchmark. The transport of sediments also depends on the speed in the pipe, its internal diameter and the waste generated.
  • From 2,500 to 3,500 US gallons per hour. This range corresponds to about 9.5 to 13.2 m³/h. A flow rate of 14 to 15 m³/h may be considered if the available level deviation covers line head loss at this flow rate.

How water flows in gravity

The pump, placed after the filter, returns the water to the pond. In operation, the level at the inlet of the filter is lower than that of the pond. This difference in level provides the height of water necessary to circulate the water in the pipe of the bottom drain.

Pond connected to a gravitary filter by a bottom drain PondFilter Level deviation Bottom drainDrive 110 mm
In motion, the water flows from the pond to the filter through the bottom pipe.

The flow tables for sloped storm discharges describe another flow rate. For a fully functioning pond line, the flow rate depends on the available height and head loss due to length, inner diameter and connections. Reference on head loss

Check its installation

Take 10 m³/h as the starting estimate, then check the pump flow rate at its actual discharge height and the minimum level allowed by the filter manufacturer. A pump that removes more water than arrivals can provide at the permissible level lowers the pump-side level. Depending on the installation, it can suck air or stop if it has protection against dry running.

Once the circuit is in operation, measure the actual flow rate and observe the levels with the clean filter, then before it is cleaned. Also check for sediment build-up when draining the pipe.

What is the radius of action of a gravitational background?

For a 110 mm bottom drain, count about 1.5 m radius, or 3 m diameter, as a marker for placing the bottom drain. The area actually cleaned depends on the flow and circulation of water near the bottom.

Aqua Rev indicates a radius of about 1.5 m for its 110 mm air model. Koiconnect recommends a bottom drain of 110 mm for 5 to 7 m² of background. If it represents this surface by a disc, this corresponds to a radius of approximately 1.3 to 1.5 m. Aqua Rev form · Koiconnect plug

What determines the collection area

In gravity, the difference in level between the pond and the filter moves water into the pipe. At comparable flow and circulation near the bottom, both modes can cover a similar area. If the flow or currents change, the collection area may also change.

  • The background profile. A gentle slope towards the bottom drain helps the waste to reach the low point.
  • The orientation of refoulement. Near-bottom water returns, including tangential returns (TPRs), can guide sediments to the bondage.

The points to be taken into account for the construction of the pond

For this example, an in-service flow rate equal to 50% of the volume of the pond per hour is used. For 100 m³, this gives 50 m³/h, which is a theoretical renewal every two hours. To place the bottom drains, one takes about 3 m between their centres as the first marker, to adjust according to the form of the bottom and the orientation of the discharges.

Example for a pond of 100 m³

  1. Targeted total debit · 50 m³/h in service.
  2. Skimmers flow rate · Two skimmers at 10 m³/h each represent 20 m³/h.
  3. Remaining flow rate for bottom drains · 50-20 = 30 m³/h.
  4. Number of bottom drains · At 10 m³/h per 110 mm bottom drain, allow three drains for the available 30 m³/h. Position them to cover the pond floor. If the floor area calls for a fourth drain, increase the combined drain flow to at least 32 m³/h and balance the pipes so that each drain reaches the 8 m³/h guideline, limiting sediment deposits. Four drains sharing 30 m³/h equally would each receive only 7.5 m³/h. If the skimmers still take 20 m³/h, the total flow must therefore reach at least 52 m³/h.

Choose the pump taking into account head loss

The pump must provide 50 m³/h in service. In this example, the return is done directly into the pond, without elevated discharge. To read the pump curve, take into account the head loss of the return circuit and the operating level deviation between the pump compartment and the pond. On the gravitational side, the slight difference in level between the pond and filter inlet allows water to flow through bottom drains and skimmers. Also check that the filter accepts the target flow rate.

  • Fixed flow pump. A model announced at 60 m³/h may be suitable if its curve indicates about 50 m³/h under circuit conditions.
  • Adjustable pump. A model announced at 100 m³/h can be considered if its adjustment range allows to reach 50 m³/h under these same conditions. Set it to the measured flow rate in service.