Measure water quality and calculate NH₃
What parameters do you measure?
Note the date, time, temperature and unit indicated on each test. During cycling, follow together total ammoniaal nitrogen (TAN) and nitrites. In routine maintenance, also follow pH, KH, GH, nitrates and dissolved oxygen. Measure salinity if you need to follow a salt intake.
A TAN test covers NH₃ and NH₄+. Raise the pH and temperature at the same time to interpret the free NH₃ portion. Check whether the nitrite test is expressed as NO₂− or NO₂–N before comparing it to the table. UF/IFAS · Interpretation of tests.
Which electronic devices complete the drop case?
The suitcase remains convenient for KH, GH, nitrites and total ammonia. To complete this equipment, I would start with an oxymeter.
Oxymeter
Choose a model with mg/L, saturation percentage and temperature. YSI Pro20i uses a membrane probe. Hanna HI98198 An early morning survey is useful in the summer.
pH-meter
L-l-Apera PH60 measures pH. Hanna HI98129 Also measure conductivity. Plan calibration and storage solutions of the probe.
Photometer and salinometer
The photometer gives an encrypted reading with reagents. It is useful if you do not distinguish the colors well. For a salinometer, check the announced accuracy at low salinity, in the range of your pond.
Water values in current maintenance
Benchmarks for a freshwater koi pond with established biological filter. The targets below apply to routine maintenance.
| Parameter | Benchmark | Reading |
|---|---|---|
| pH | 6.5 to 8.5, stable | Compare measurements taken at similar times. |
| KH | > 100 mg/L as CaCO₃ (≈ 5.6 °dKH) | Indicates the buffer power of the water. |
| GH | > 100 mg/L as CaCO₃ (≈ 5.6 °dGH) | Reflects mainly calcium and magnesium. |
| Nitrites (NO₂-) | Not detectable | Check the detection limit of the test. |
| Free ammonia (NH₃) | Not detectable | Fraction calculated from TAN, pH, and temperature. |
| TAN (NH₃ + NH₄+) | Not detectable | Total measured by the test. Check its unit and interpret the result with pH and temperature. |
| Nitrates (NO₃−) | < 20 mg/L NO₃ - | Follow the trend and check the unit of the kit. |
| Dissolved oxygen | Close to saturation, above 5 mg/L | 5 mg/L is a low threshold. Saturation depends in particular on temperature. |
| Salinity | Fresh water, without current salt addition | Follow the reference value of your pond if you measure salinity. |
Aquatic Veterinary Services · Spokespersons for Koi · Merck · Freshwater quality · Aquatic Veterinary Services · Salt in pond
Interpret the TAN in your pool
You are right to want to interpret TAN (Total Ammonia Nitrogen, or total ammonia nitrogen) based on pH and temperature. This is an essential distinction: your drop test measures TAN, but the actual toxicity to your fish depends on the fraction that turns into free ammonia (NH₃) due to pH and temperature effects.
This is how this relationship is interpreted in practice.
What your test (TAN) measures vs. what is toxic (NH₃)
TAN is the sum of two forms of ammonia in water:
- NH₄+ (ionized ammonium) : It is the majority form and much less toxic.
- NH₃ (free or non-ionized ammonia) : It is the most toxic form, because it easily passes through the gills of fish and accumulates in their blood.
Your drop test therefore gives you the "total". To know the real danger, you have to calculate the NH₃ share.
The two factors that make the TAN shift to toxicity
Two parameters in your pond determine the percentage of TAN that becomes toxic NH₃:
- pH (most influential factor) : The higher the pH (basic), the higher the NH₃ share. On the other hand, slightly acidic water (pH low) keeps ammonia as NH₄+ less dangerous.
- Temperature : The warmer the water, the higher the proportion of NH₃. This is particularly critical in summer, as heat accelerates the metabolism of fish (thus their production of waste) while increasing the toxicity of these wastes.
How to do the concrete calculation (method)
You don't need to be a mathematician, just use a conversion table (or an online calculator below). The method is simple:
- Measure the TAN with your suitcase (e.g. 0.5 mg N/L).
- Measure pH (e.g. 8.0).
- Measure the temperature (e.g. 25 °C).
- Look for the conversion factor corresponding to this pH/Temperature torque in a reference table.
Let us take a concrete example from the standard conversion tables (values vary slightly depending on the source, but the logic is the same):
- At pH 7.0 and 25 °C, approximately 0.56% of the TAN is NH₃. For an TAN of 1 mg N/L, this gives 0.0056 mg N/ L NH₃–N, or 0.0069 mg/L NH₃.
- At pH 8.0 and 25 °C, the proportion rises to about 5.4%. With the same TAN of 1 mg N/L, this gives 0.054 mg N/ L NH₃–N, or 0.065 mg/L NH₃. The NH₃ concentration is approximately ten times higher.
- At pH 8.0 and 30 °C, the proportion reached about 7.4 %. For the same TAN, this represents 0.090 mg/L of NH₃.
To be kept in mind
To interpret your results, keep these benchmarks (which concern NH₃ free, not total TAN):
- Alert threshold — As early as 0.05 mg/L of free NH₃, gill damage may occur, and sensitivity varies depending on fish and pond conditions. Merck Veterinary Manual
- Hazard zone levels greater than 2.0 mg/L can be fatal.
- Maintenance objective : In a balanced pond, the TAN should be undetectable or close to zero. If you detect TAN, the NH₃ calculation will tell you how urgent the situation is.
How it changes for your maintenance
- Do not panic on a slightly positive TAN if the pH is low : At pH 7 and fresh water, a measurable TAN is often not dangerous because it remains in the form of NH₄+.
- Be much more vigilant with high pH + hot water : This is the most risky combination. An TAN that would appear to be "tolerable" at pH 7 becomes critical at pH 8.5 in summer. That's why monitoring the pH in parallel with ammonia is essential.
- The KH is your ally : A stable KH avoids sudden drops of pH. But be careful, a pH that remains high (e.g. 8,5) due to very hard water will maintain a higher toxic fraction. The ideal is a stable pH around 7,5-8,0, not necessarily as low as possible, but especially without fluctuations.
- In case of peak If the calculation indicates a level of NH₃ concern, adjust the water change to fish measurements and condition. Check the replacement water before using it and re-measure the TAN, pH, and temperature after the change.
In summary : your TAN test is the raw material, but pH + Temperature are the hazard multipliers. A TAN of 1 mg/L does not at all have the same meaning depending on whether you are at pH 7/cold water or pH 8.5/hot water.
NH₃ ammonia calculator
For a freshwater pond, enter the measured TAN (ammonium and ammonium combined), pH and water temperature.
The result passes in red from 0,05 mg/L NH₃ free.
Check the unit in the package leaflet of your TAN test before calculating. Freshwater formula (EPA) · Reference Global Seafood Alliance