The world of koi and garden ponds

UVCs

UVCs are essential devices to keep the water clear in your pond. Indeed, the development of unicellular algae responsible for green water is inevitable. UVC is the only way to counter the appearance of these algae.

The topics addressed in this article are:

Why a UV lamp?

  • How to install a UV?
  • Choice and power of the UV
  • Composition of a UV tube
  • How long after the unit is installed, will the pond water clear?
  • Maintenance
  • Comparison between TL and PLS lamps (L)
  • Why are tubes more effective?

Why a lamp UV? 

The UV lamp helps to contain the development of single-cell algae, in particular to avoid having green water.

This lamp becomes really useful when your piece of water is exposed in the sun. In this case, the development of algae is very fast.

Choice and Power UV

  The choice of UVC will be determined by the volume of water in your pond. Indeed, there are a wide variety of models, sometimes even adapted directly to the filter. The type of exposure is essential (very sunny tank). It will also determine the power of UVC and, finally, the maximum flow of your pump. Indeed, these devices are designed for a certain flow beyond which they are no longer effective. The best thing is to have your distributor advise you by reporting the elements described above.     

UVC placement diagram according to operating modes

Four UVC placement configurations in a pond

Composition a UVC tube apparatus

Broken view of a UVC device with five numbered pieces
1. Rubber plug of electrical connection · 2. Compression connection · 3. O-ring · 4. UV lamp · 5. Quartz sleeve.

How much In time after installing the unit, will the water in the pond clear?

If your unit is properly sized and installed, the water becomes clear again within 3 to 14 days. However, the unit must be kept active at all times in order to avoid reformation of the green water.  

General comment on UVCs

Attention! UVC, as mentioned above, treat unicellular algae responsible for green water but, In no case are filamentous algae.

Maintenance

The lamp has a useful duration of about 7,000 to 12,000 hours. Since the UV must operate from spring to October, 24 hours a day and 7 days a week, the lamp must be changed once a year. These devices usually do not support the frost. Disassembly, discharge and cleaning are advised before freezing. If you want to let your filter work, don't forget to make a type-by-pass connection with quick connections, which will be a considerable ease and save time. An example is given at the end of the article.

If your water does not lighten up after prolonged use, it is possible that the quartz surrounding the UV lamp will be sealed or dirty. In case of articulation, clean the quartz with vinegar. To do so, use paper wiped all with vinegar. Leave to act for an hour. Then rinse the quartz and wipe it with a dry towel.

If the quartz is dirty, rinse it and dry it with a dry towel.

Comparison between TL and PLS lamps (L)

The comparison uses Philips data from the publication “Philips lighting – Disinfection by UV-radiation no. 322 634 00671-8/92, Printed in the Netherlands”.

We will see that TL lamps are more effective than PL (S)L lamps.

Comparison between a straight TL lamp and a two-ply PLS(L) lamp
TL lamp on the left and PLS lamp (L) on the right.

One of the most important arguments is the "morphology" of the UV-producing plasma: in TL tubes, the plasma is uniform and distributed without disturbance from one end to another of the tube, and throughout its periphery. In PLS tubes (L), the plasma emitted by one branch of the tube disturbs that of the other and vice versa. This results in partial absorption and disruption of UV radiation, resulting in lower efficiency at equal power. 

Cut of TL and PLS(L) lamps with purple halos and marker between the two strands
Plasma distribution
TL, left: The purple halo represents a uniform plasma around the tube.
PLS (L), right: the arrow indicates the area between the two strands where the original diagram shows a disturbance of the radiation.

Why are tubes more effective?

Cutting of TL and PLS(L) lamps in their quartz sleeves
Temperature around lamps and quartz sleeve
TL, left: uniform orange ring shows the regular temperature indicated on the original diagram, about 40 °C.
PLS (L), right: The orange and blue alternation illustrates the warmer and cooler areas around the sleeve. The colours are indicative.

In addition to the evidence described above, the following arguments support the hypothesis of effectiveness on the very principles of germicide radiation:

  • TL tubes are longer than PLS (PLL), organisms to be killed (algae, bacteria, etc.) undergo longer exposure and therefore receive a higher UV dose.
  • The temperature of the lamp is more uniform around the TL tube, so the efficiency of UV radiation will be greater around a TL than with a PL. 

Conclusion:

The main thing is to place a UV. It is often easier to place a PLS tube that integrates into the filter, rather than a TL that is external to the filter, as it is also necessary to take into account the aesthetic aspect, since a TL tube is not always easy to hide. 

Germicide aspect of UVC

I would call them an urban fable, they're germicides and they are, it's negligible.

However, there is a UVC in the pond trade which is germicidal: it is the " BIO UV". It is a FRANCAIS product but, in this case, if we do not take into account the price of the beast, there is also consumption!

To give you an idea, the SMPVC 75 model has a consumption of 1.5kW. This model is designed to process 20 m³/h, i.e. a pond of up to 40m3. The following model can handle 65m3/h with a consumption of 3kW; therefore nothing to do with conventional UVC in our ponds!

So I'm asking you a question, what are you going to do with your 75W UVC? A Bio UV is just 20 to 40 times more powerful. The BIO UV becomes really germicide!

BIO UV group reference

I'll leave you the link in case http://www.bio-uv.com/

Classic UV-C lamp or amalgam lamp?

Both technologies use low-pressure mercury vapour to produce primarily UV-C radiation at 254 nm. In an amalgam lamp, a mercury reserve is linked to other metals in the form of alloying. This technology allows for higher UV-C power density and more stable efficiency over a wider temperature range.

Excelitas · Amalgam UV-C lamps · Helios Quartz · Composition of amalgam

CriterionClassic UV-C lampAmalgam lamp
Power per lamp lengthLower to comparable length.Higher. The exact gain depends on the model.
TemperaturePerformance more sensitive to operating temperature.Generally more stable yield. Some ranges are provided for an atmosphere of 4 to 40 °C.
DurationTo be checked on the lamp form and the clarifier package leaflet.Example manufacturer range, from 12,000 to 16,000 nominal hours. The replacement interval depends on the device.
MaintenanceQuartz cleaning and lamp replacement according to the package leaflet.The same checks are still necessary, even with a longer useful period.
Lamp bristlesPresence of mercury, necessary precautions.Presence of mercury in alloy and steam during operation, precautions required.

Light Sources · Power density and temperature · ZED · Nominal duration of amalgam lamps

What's the point of a pond?

An amalgam lamp can process a higher flow rate in a compact unit. The result also depends on the water transparency, the passage time and the design of the reactor. Choose the UV-C set according to the permissible flow rate specified by the manufacturer, the intended use and the conditions of the tank.

The electrical power consumed and the UV-C power emitted are two different values. The power ranges and temperature ranges vary from one device to another. A lamp and its ballast must be compatible.

UVC submerged

In the fight against the green water of garden ponds, due to floating microscopic algae, the most effective way in the world of the pond is the treatment by ultra-violet.

Most ultra-violet devices (UVCs) for a koi pond are generally systems to be connected in line into the filtration circuit. In gravitational filtration, UV will preferably be placed after filtration, towards return to the pond. In pumped filtration, UVs will be placed before filtration.

Both systems have a common disadvantage: to pass the water through these systems, it takes a powerful pump to avoid head loss.

Illustration of the article on UVC

Ultraviolet are radiations normally emitted by the sun that cover a range of 100 to 400 nm (nanometre):

  • – Uv-A: the beach is between 315 and 400nm, mainly responsible for tanning the skin.
  • – Uv-B: the range is between 290 and 315 nm, they are responsible for producing vitamins in the skin.
  • – Uv-C: in the range of 200 to 290 nm are responsible for the destruction of cells by action on the DNA molecule.

A wavelength between 254 and 260 is the most effective range to damage this DNA molecule. Cells have the ability to repair themselves, which is why UV efficiency depends on 2 elements:

  • the intensity and duration of exposure: microwatt second /cm². This value therefore depends on the number of Watts as well as the time that the water is exposed to UV. This value must be around 30,000microW second/cm².
  • For conventional UVs, there are between 2 to 5 watts/m³ of water in the pond, depending on the exposure. The speed of passage is given by the manufacturers. In these systems, therefore, it is not necessary to exceed this speed, which is usually expressed in m³/h.

These Watts correspond to the electrical consumption of these lamps and not to the UV watts produced which are much lower.

Some UVs, to increase their efficiency, are built in stainless steel to have a UV reflecting effect. All these UVs have a lifetime of +/- 7,500 hours (one season), after which the intensity decreases and no longer reaches the 30,000 microw second/cm².

Illustration of the article on UVC

This is why a UV submerged is more efficient and without head loss that can be placed anywhere or almost:

  • in a vortex
  • under a grid filter (allowing in addition to keeping free the grid of the bacterial film)
  • in the pumping chamber
  • above a biological filtration chamber (but protecting the filter mass)
  • in a drum filter

Characteristics:

  • wavelength: 254nm, 15 watts (for 36 watts consumed)
  • light ozone production
  • IP 68
  • duration: 12,000 hours

We performed a test:

  • a koi pond of 150 m³ comprising 40 koi of 60-80 cm
  • Test during the month of August, pool exposed from 8:00 to 18:00 hours without shadow.

First day of the test, water is green.

Illustration of the article on UVC
Illustration of the article on UVC

Launch of the 36-watt UVC submerged on day 1

Illustration of the article on UVC
Illustration of the article on UVC

This UVC is, in this installation, placed in the pump chamber before the water returns to the pond (flow:80m3/h).

Illustration of the article on UVC

After 48h00, single-cell algae died largely because they no longer influence the PH and oxygen concentration measured continuously by IKS.

Illustration of the article on UVC
Illustration of the article on UVC

Why a By-pass?

When winter arrives, it is imperative to remove the UVC. Why? This one does not support the frost. Your UVC is connected to the pump that supplies the filter via clamps. Successive dismantling and winding may damage the input of UVC. For quick assembly and disassembly, the solution is to make a By-pass.

View of the finished By-pass ready to be mounted at the foot of the filter. It consists of three guillotine valves, and four quick connections adapted to the diameter of the pump pipe. The diameter of the tubes may be greater than the cross section of the filter pipe, but in no case less. In this case, the cross section is 50mm

Illustration of the article on UVC

Equipment necessary:

2 x T to be glued

Illustration of the article on UVC

2 x quick connections 

One side is male threaded, the other side is to stick 

Illustration of the article on UVC

2 x Reductions for the adaptation of pipes from the pump to the filter.

A tube length of the selected diameter.

Illustration of the article on UVC

It's time to start editing

Place all the parts on the ground to visualize your mounting. Take carefully the measurements between the axis of your UV and saw the different pieces to glue.

Illustration of the article on UVC

The deburring is an essential operation so that the parts fit perfectly. A light sanding of the parts to be glued allows a better adhesion of the glue.

Illustration of the article on UVC
Illustration of the article on UVC

Glue the male parts and firmly bind the two pieces. Adjust to get the right mounting angle. 

Illustration of the article on UVC
Illustration of the article on UVC

To facilitate the installation, proceed as on the image. Mount both columns first. This makes it easy to measure the length of the two central parts. 

Illustration of the article on UVC

After the installation of the two central parts, the assembly is complete.

Illustration of the article on UVC

In the images below, you can see the UVC disassembly in one turn. Only the final installation is left near the filter. 

Illustration of the article on UVC
Illustration of the article on UVC

For safety, it is preferable to cut the pump before handling the valves.

Calculate the UV-C power and flow rate