The world of koi and garden ponds

The JFR Koi Pond — The filtration system

Fifth and last part · Equipment and circuits

JFR presents the filtration choices of its pond and the assembly of circuits. The characteristics quoted correspond to the equipment of the reportage.

The choice of filtration

Filtration is the essential, vital element of a pond. Whatever the technology used, it is important that it be sufficiently dimensioned (oversized in the absolute does not exist). Why sufficient? A fish, especially the koi, pollutes the water already by breathing alone, the water coming out by its gills being charged in ammonia.

The highly toxic ammonia, since it is lethal, must undergo a transformation Nitrite, Nitrate passing in the filter its "vital" balance. The nature of the materials used in filtration systems offers a support for colonization of beneficial bacteria (the motor of ammonia transformation), more or less elevated. There is no good or bad support, everything will depend on the volume offered to bacteria to work and consume all ammonia, a coefficient that must be taken into account in order to dimension accordingly the volume of this medium, more precisely at the density of the koi contained in the pond.

Very schematicly, the smallest is the material, the highest is the ability to colonize bacteria. The sand filter, even more the fluidized sand filter offers an exceptional surface/colonisation ratio for a very small filtration volume... In return, this support gets crushed very quickly and requires a lot of handling. On the other hand, the Japanese mattress offers a lesser support, its saturation is less rapid but its volume (m²) must be substantial to offer all the necessary support for the bacteria. Intermediate offers highlight fluidized filters with "plastic" balls, their very low density puts them in motion in the filter (pressure), the colonization surface is excellent (about 1,600 m² per m³ of biomass, 6 times less for the Japanese filter matting) for a floor covering of 1 m².

For all these reasons, I opted for this type of filter for my pool. Zoom below:

UltraBead Bead Filter

The illustration opposite the Ultrabead filter highlights the thickness of the balls offering a thick mattress of filter material.

Lighter than water, it blocks at the top of the filter, the water arriving in A returns to the pond by C under pressure, it passes through all layers.

The cylindrical shape of the filter and the blades of rotor A give a permanent movement to the balls... favoring exchange and better oxygenation of the mattress, increasing the oxidation effect of ammonia.

The D-head is an agitator used for maintenance operations, it propels pressured air into the filter. The dirts are taken off and fall under gravity in the bottom of the tank to be removed manually in B.

UltraBead 3D filter cut with ball bed, A arrival, B purging, C collector and D blower
UltraBead Bead Filter with 3D cut · Illustration 1 · Click to enlarge.

Purge valves and ventilated bottom drains

The photo opposite shows the first element of the assembly connected to one of the bottom bottom drains of the pond.

The PVC return comes out at the level of the technical chamber. A ball valve is mounted as low as possible in the chamber to purge and clean the PVCs from the pond by pressure. This is made necessary to avoid the eventual sealing of PVCs by sedimentation effect (the heaviest waste not able to climb in gravity and therefore cannot be removed from the circuit).

A guillotine valve is used to cut/open the supply of the prefilter for the bottom drains. The flexible 10 mm reinforced and transparent hose will be used to supply the domes with air-loaded bottom drains via the pumps (up to 12 m³ air / hour).

Purge valves and ventilated bottom drains — illustration 2
Purge valves and ventilated bottom drains · Illustration 2 · Click to enlarge.

The level of gravitational prefilters

The photo on the right shows the attention that has been paid to the ground levelling relative to the height of the prefilter (gravite).

A floor too high, the water will not feed filtration, too low... the technical house would be flooded.

The level of gravitational prefilters — illustration 3
The level of gravitational prefilters · Illustration 3 · Click to enlarge.
The level of gravitational prefilters — illustration 4
The level of gravitational prefilters · Illustration 4 · Click to enlarge.
The level of gravitational prefilters — illustration 5
The level of gravitational prefilters · Illustration 5 · Click to enlarge.
The level of gravitational prefilters — illustration 6
The level of gravitational prefilters · Illustration 6 · Click to enlarge.
The level of gravitational prefilters — illustration 7
The level of gravitational prefilters · Illustration 7 · Click to enlarge.

The two filtration lines

The filtration system is powered by two bottom bottom drains, two intermediate bottom drains.

Each pre-filter (200 microns) is powered by 1 bottom and 1 wall.

A prefilter conveys water from the pond via an ITT pump (16 m³/h), a filter, a UV (55 and 110 W), a heating system with electronic temperature control.

Global view of the filtration system.

The two filtration lines — illustration 8
Both filter lines · Illustration 8 · Click to enlarge.

Independent filtration by circuit

The large filter, capable of treating 95 m³ in a loaded pond with 200 kg of koi, would have been enough to feed and treat the pond alone (43 m³). However, I preferred to double the filtration line by addressing each couple (full background and wall) independently.

This more expensive system offers an optimisation of the flow compared to a series installation and a system that is always operational during maintenance.

Independent filtration by circuit — illustration 9
Independent filtration by circuit · Illustration 9 · Click to enlarge.
Independent circuit filtration — illustration 10
Independent filtration by circuit · Illustration 10 · Click to enlarge.
Independent circuit filtration — illustration 11
Independent filtration by circuit · Illustration 11 · Click to enlarge.

Waste retention on the grid

Zoom on the obvious interest of grid prefilters and work in gravity-fed mode.

The particles remain blocked on the grid, ideally the koi's dejections are not broken by the blades of the pumps (actually increasing water pollution) ... since simply sucked from the pressure of the prefilter bottom drain.

A float constantly adjusts the height of the water to avoid congestion of the prefilter.

Thus, the water level is always the same in the bottom of the tank, by its fall the water is oxygened in an optimal way.

Detention.

Aeration.

Maximum ventilation of the water before working in the filter.

The retention of waste on the grid — illustration 12
Waste retention on the grid · Illustration 12 · Click to enlarge.
The retention of waste on the grid — illustration 13
Waste retention on the grid · Illustration 13 · Click to enlarge.
The retention of waste on the grid — illustration 14
Waste retention on the grid · Illustration 14 · Click to enlarge.

Pipe diameters and UV

If the prefilters have two 110 mm flow-promoting arrivals, the output is dimensioned in 50 mm offering a standard market on pumps, filters, UV.

The reduction in 50 mm is not binding here, the pump offers a constant flow (16 m³ hour, minus head loss due to PVC length, number of elbows, PVC diam, etc.).

When working in a pressure filter, the UV must always be mounted after the filter. In this way, the UV works optimally.

Pipe diameters and UV — illustration 15
Pipe diameters and UV · Illustration 15 · Click to enlarge.

Winter operation and water returns

My choice to feed the pond both through bottom and middle (mural) bottom drains allows me to cut in winter the bottom bottom drains to leave only the murals and avoid too much cooling of the pond and thus avoid fatigue of the koi by a very important background current.

The photo on the right also shows the water returns which allow to reverse the direction of the current. The same system exists for the second filter.

Winter operation and water returns — illustration 16
Winter operation and water returns · Illustration 16 · Click to enlarge.
Winter operation and water returns — illustration 17
Winter operation and water returns · Illustration 17 · Click to enlarge.
Winter operation and water returns — illustration 18
Winter operation and water returns · Illustration 18 · Click to enlarge.

JFR's report